Product Parameters:
Digital input channel: 16 channels (active low)
Operating temperature range: -20 ° C ~ 70 ° C
External power supply: DC9V~30V/2W
Isolation protection: 1500VDC
Installation method: standard DIN rail mounting or screw mounting
Dimensions: 125*73*35mm
Features:
RS485 MODBUS RTU standard communication, can be networked with configuration software, PLC, industrial touch screen, etc.
With communication and input and output status indicators
Communication circuit adopts lightning protection and anti-interference design
Can be widely used for signal acquisition and control of industrial field devices
Instructions for use:
1. Connect the computer and module with RS485 converter
2. Connect the 12V or 24V external power supply to the module and power it on. To avoid unnecessary damage, please check whether the
positive and negative terminals of the power supply are connected correctly before powering on.
3. Open the debugging software, select the corresponding module model, enter the function debugging or parameter setting interface
4. Set the correct communication parameters, open the communication port
5. Select the appropriate settings, acquisition and control options
Package:
1* analog input module
Digital input channel: 16 channels (active low)
Operating temperature range: -20 ° C ~ 70 ° C
External power supply: DC9V~30V/2W
Isolation protection: 1500VDC
Installation method: standard DIN rail mounting or screw mounting
Dimensions: 125*73*35mm
Features:
RS485 MODBUS RTU standard communication, can be networked with configuration software, PLC, industrial touch screen, etc.
With communication and input and output status indicators
Communication circuit adopts lightning protection and anti-interference design
Can be widely used for signal acquisition and control of industrial field devices
Instructions for use:
1. Connect the computer and module with RS485 converter
2. Connect the 12V or 24V external power supply to the module and power it on. To avoid unnecessary damage, please check whether the
positive and negative terminals of the power supply are connected correctly before powering on.
3. Open the debugging software, select the corresponding module model, enter the function debugging or parameter setting interface
4. Set the correct communication parameters, open the communication port
5. Select the appropriate settings, acquisition and control options
Package:
1* analog input module